Class II Biological Safety Workstation

Reliable biological safety environment with small footprint


DreamLab® DL-BSW series Class II Biological Safety Workstations are developed for working with potentially hazardous samples during life science experiments, providing protection to both sample and operator. Airborne contaminants are captured in HEPA filtration before entering the active workspace. The exhaust air is HEPA filtered so harmful particulate is not released into the room. Compared with regular biological safety cabinets, this bench-top workstation has a quite small footprint, convenient to be moved to different sites if necessary. DL-BSW series Class II Biological Safety Workstation is constructed of white polypropylene which does not allow for bacterial build-up and can easily be cleaned with any disinfectant product. To further reduce the threat of cross-contamination, the built-in timed UV light can be used to irradiate work surfaces and tools between samples or cases. Full-closure sash and safety switch prevent operator exposure to UV energy. DLTouch microprocessor controller constantly monitors filter conditions and alerts the user if filter replacement is needed. 


II级生物安全工作台 - 斜面.png

DL-BSW100 Class II Biological Safety Workstation


标准特性图标.pngStandard Features

-  DLTouch automatic safety controller 

-  All polypropylene seamless construction

-  Recirculating airflow design provides operator and process protection

-  HEPA filter in exhaust

-  Retracting front sash frame for full chamber access

-  Clear polycarbonate sash for visibility

-  Stainless steel front perforate plate

-  Ergonomic armrest 

-  Timed shortwave UV light

-  Safety switch to prevent exposure to harmful UV energy

-  Polycarbonate and polypropylene material reflecting UV energy

-  Integral LED light

-  Constant temperature and humidity monitoring

-  Lab event timer

-  No ductwork required

-  No installation required, plugs directly into a standard 110V or 220V electrical outlet

-  Extremely quiet operation < 60dBA

-  Shipped fully assembled and tested

-  Available in 110V AC or 220V


附件选项图标.pngOptions

-  Mobile cart with casters

-  Base cabinet

-  ULPA filters


工作原理图标.pngHow does it work?

II级生物安全工作台气流图.jpg

  1. Room air enters at A where it is pulled into the lower baffle, a perforate plate under sash, along with a portion of the chamber air.

  2. Air travels through the lower baffle and up the rear baffle. Chamber air is mixed with room air at B before moving into the filtration area at C.

  3. The majority (approx. 70%) of air moves through the HEPA filter at D, providing ISO 5 clean air to the chamber. Remaining air is HEPA filtered and exits the enclosure at E.